EURO 46 V10 Programming Manual
Appendix 1 - Input Types
No
Input Types
Operation
00
Unused
Factory default. Input is disabled.
01
Fire
Active at all times.
Audible Response: Differentiated Internal sound. Pulsed external sound.
Communicator: ‘Fire’ signal
02
Gas
Active at all times.
Audible Response: Full ex Internal sound.
Communicator: ‘Gas’ signal
03
HU
#
Active at all times.
Audible Response: Differentiated Internal sound. Full external sound.
Communicator: ‘Hold Up’ (PA) and ‘Input HU’ signals
04
Silent HU
#
Active at all times.
Audible Response: None
Communicator: ‘Hold Up’ (PA) and ‘Input HU’ signals
05
Tamper
When unset:
Audible Response: Internal only. Communicator: ‘Tamper’ signal.
When set:
Audible Response: Full exInternal sound. Communicator: ‘Tamper’ signal.
06
Intruder
Active when set:
Audible Response: Full ex Internal sound.
Communicator: ‘Intruder’ and ‘Unconfirmed’ signals
07
Final Exit
(FX)
# $
Active when set:
– initiates entry timer if system not unset before entry time expires: Audible
Response: Full.
Communicator: ‘Intruder’ and ‘Unconfirmed’ signals.
08
Entry Route
(ER)
$
Active when set
, except during entry time.
Audible Response: Full.
Communicator: ‘Intruder’ and ‘Unconfirmed’ signals.
09
ER
(Area FX)
When fully set
, acts as ‘Entry route’ input, as above. When part set, acts as ‘Final Exit’ input, as
above.
10
FX
(Area ER)
When fully set
, acts as ‘Final Exit’ input, as above. When part set, acts as ‘Entry Route’ input, as
above.
11
PTS
Active during exit time
to complete Setting procedure
No audible or communicator response.
Note: May be used to act as ‘doorbell’ by use of ‘chime’ attribute.
12
Switcher
Active at all times:
This Input Type is used when you want an input to be used to trigger an output,
but not an alarm. It will function whether the panel is set or unset and can be used to illuminate
a light, or trigger a CCTV camera etc. NOTE: If the input has Masking or Tamper functions – then
these will still trigger an alarm, it is only regular activations that will not.
13
Day Alarm
When set
: Internal (‘beep’) Response: Full; Communicator: ‘Instant’ signals.
When unset:
Audible (sounder) Notification: Programmable; Communicator: ‘24hr Alarm’ signal (if
programmed in Alarm Responses menu).
15
Ward Control
Input is allocated by system software and cannot be reprogrammed to a different type, though
relevant attributes may be adjusted.
16
Fault
When set
: Audible Response: Full; Communicator: ‘Instant’ signals.
When unset:
Audible Response: Programmable; Communicator: ‘24hr Alarm’ signal (if
programmed in Alarm Responses menu).
17
Closure Supervision
Active during Setting procedure
. No audible or communicator response. Prevents system being
set whilst active.
18
Shunt Input
Active at all times
. No audible or communicator response. Accepts input from key-switch (or
equivalent) to shunt the inputs assigned to it. Associated outputs are available. After 10 seconds
the detectors in the shunt list will be active.
19
Unset Input
Active when set.
Accepts input from key-switch (or equivalent) to unset the Area/Level set
assigned to it.
20
Keyswitch Latched*
Accepts input from key-switch (or equivalent) to set/unset the areas assigned to it. Setting includes
normal exit time, etc. Requires latching action switch.