32
EURO 46 V10 Programming Manual
Silent 1st Alarm
If this function is selected as ‘confirmed’, then the first alarm to be activated on the system will be
silent, but if another input activates (i.e. a confirmed alarm) then the alarm tones will be heard. This
option is only valid once the system has been set for 3 minutes and if the entry time has not been
initiated. The default setting is ‘Never’.
Disable Confirm On Entry
To comply with BS8243 clauses 6.4.3 and 6.4.4, this option should be set to ‘Yes’ to disable
confirmation once the entry procedure has started. For use with BS8243 option 6.4.5, this option
should be ‘No’. If ‘Disable Confirm On Entry’ is set to ‘Yes’ this option will disable all confirmation
signals on entry. If ‘No’ is selected, the confirmation signals are enabled on the expiry of the entry
time.
Area A, B, C, D, 0, 1, Starts at:
This feature programs where the alarms for each area A, B, C, D, 0, 1 start: ‘Keypads’, ‘Internal
Sounders’, ‘Sirens Only’ or ‘Digi’.
Area A, B, C, D Stops at:
Alarms for each area can stop at: ‘Keypads’, ‘Internal Sounders’, ‘Sirens Only’, ‘Digi’ or ‘Confirm’.
Fire Alarm Starts at:
This feature programs the starting point of the alarm responses for a fire alarm. The levels are:
‘Keypads’, ‘Internal Sounders’, ‘Sirens Only’ and ‘Digi’.
Fire Alarm Stops at:
This feature programs the ending point of alarm responses for a fire alarm. Chose from: ‘Keypads’,
‘Internal’ ‘Sounders’, ‘Sirens Only’ and ‘Digi’.
Gas Alarm Starts at:
This feature programs the starting point of the alarm responses for a Gas alarm. The levels are:
‘Keypads’, ‘Internal Sounders’, ‘Sirens Only’ and ‘Digi’.
Gas Alarm Stops at:
This feature programs the ending point of alarm responses for a Gas alarm. Chose from: ‘Keypads’,
‘Internal’ ‘Sounders’, ‘Sirens Only’ and ‘Digi’.
HU Alarm Starts at:
This feature programs the starting point of the alarm responses for a HU alarm. The levels are:
‘Keypads’, ‘Internal Sounders’, ‘Sirens Only’ and ‘Digi’.
HU Alarm Stops at:
This feature programs the ending point of alarm responses for a HU alarm. Chose from: ‘Keypads’,
‘Internal’ ‘Sounders’, ‘Sirens Only’ and ‘Digi’.
Medical Starts at:
This feature programs the starting point of the alarm responses for a 24 hour alarm. The levels are:
‘Keypads’, ‘Internal Sounders’, ‘Sirens Only’ and ‘Digi’.
Medical Stops at:
This feature programs the ending point of alarm responses for a 24 hour alarm. Chose from:
‘Keypads’, ‘Internal’ ‘Sounders’, ‘Sirens Only’ and ‘Digi’
Содержание Pyronix EURO 46 V10
Страница 62: ...62 EURO 46 V10 Programming Manual...
Страница 63: ...63 EURO 46 V10 Programming Manual...
Страница 64: ......