25
EURO 46 V10 Programming Manual
Option
Description
Common Lobby?
If ‘Yes’, this will automatically prioritise the exit modes for each area:
(0 = Timed, 1 = Final Door, 2 = Timed/Final Door, 3 = PTS). This option is only relevant when Final
Door option is used on a system with different areas using a common lobby.
EXAMPLE: If Area C is selected as the ‘Final Door’ setting mode and the rest of the areas are
selected as ‘Timed’, then because ‘Final Door’ is higher priority, the users of every individual area
must follow the ‘Final Door’ route to the exit - making this door a ‘common for all areas’. If set to ‘NO’
the exit modes will be individually programmable to each area.
Flexi Unset
When enabled, this setting will allow users to select which areas they unset (from the areas that they
have been permitted to unset).
2 Key HU
If the
1
and
7
keys are pressed and held together for a period of time (programmed in the
keypad menu), a 'Hold Up' will occur.
If ‘NONE’, the keys are disabled. If ‘SILENT’, a ‘Silent Hold Up’ will be signalled. If ‘Bells Only’,
any external sounder will activate but NO signals will be sent. If ‘BOTH’, any external sounder will
activate and a signal will be sent using the DIGI-GPRS.
External ATE Inputs
Permits selection of inputs to ATE pins to suit ‘ATE’ (including RedCare Reset), ‘DigiCom’ (including
Telback), ‘Relay Interface Monitoring’ or ‘Not Used’.
NOTE: This option must be set to ‘ATE’ or ‘Digi’ in order for Line Fault, etc. monitoring to function.
This option is NOT required for use with the digi-modem.
Tag Opens Doors
This function is only used in conjunction with a reader being programmed as 'Entry Control' in
'ASSIGN KEYPADS/READERS'.
If ‘YES’ the ‘Entry Control’ readers will control the setting/unsetting and the doors. If ‘NO’ the Entry
Control readers will control the setting/unsetting only.
Set With Polling Fault
If ‘YES’ the control panel will still set even if there is a wireless polling fault. The panel will not display
a wireless polling fault.
If ‘NO’ the user will not be able to set the panel with a polling fault. The panel will display a fault and
the setting procedure will be stopped.
Fob Unset Entry
If 'YES' any wireless key fobs learnt will only be able to unset the panel once the entry timer has
been activated. If ‘NO’ any wireless key fobs learnt will always be able to set and unset the Control
Panel.
Wireless Bell Supervision
If 'YES' then the wireless external sounder will go into alarm if it can no longer communicate with the
control panel / Wireless ZEM.
Download if Set
If 'YES' any upload/download procedures will be possible on the InSite software regardless of the
set/unset status of the Control Panel.
UDL/Cloud Priority
If this is set to ‘high’, the Cloud signalling will take priority over ARC signalling events (may delay
them slightly) to maintain a smooth cloud connection. If the system is graded (defaulted with clean
start code 2002 for Grade 2 or 2000 for Grade 3), then this setting will default to ‘low’ so that Cloud
connections cannot delay ARC signalling events.
System Displays
Area Texts (01ABCD)
The text can be programmed for each area; such as ‘Area 0’ you may want to be ‘Full House Set’.
PLEASE NOTE:
A maximum of 16 characters is allowed.
Full Area Text
The text that is displayed when all areas are set.
Sign On Message
This is the message that is displayed in day mode.
Display When Set
If ‘Yes’, the keypad display will show the area text when that particular area is set.
PLEASE NOTE:
This must be programmed as ‘No’ to ensure compliance with EN 50131.
Display Alarms
If ‘Yes’, then the keypad display will show all alarms, without requiring a user to enter their code or
present their tag.
PLEASE NOTE:
This must be programmed as ‘No’ to ensure compliance with EN 50131.
Display HUs
If 'Yes’, then the keypad display will show any HU alarms that have occurred without requiring the
user to enter their code or tag.
PLEASE NOTE:
This must be programmed as ‘No’ to ensure compliance with EN 50131.