EURO 46 V10 Programming Manual
Appendix 2 - Output Types
No.
Output Type
Active
Restore
0000
Not Used
0001
Fire
At a fire alarm activation.
When a valid code is entered.
0002
Hold Up Any
At a hold up (HU) /personal attack activation.
When a valid code is entered.
0003
Intruder Any
At an intruder alarm from any area.
At first valid code entry.
0004
Final Set All
When ALL areas are set.
At code entry to unset.
0005
Misoperation (Abort)
When the system is silenced after an intruder
alarm has been activated.
After two minutes.
0006
Confirmed Any
After two intruder alarm activations.
At the next code entry.
0007
Tamper Any
Tamper alarm activation in any area.
At code entry to silence
and at the end of the confirm time.
0008
Duress Any
At a duress alarm in any area.
When a valid code is entered
0009
HU Device Any
At alarm on a HU input only, from any area (this
does not include the keypad HU).
When a valid code is entered.
0010
Gas
At a gas alarm
When a valid code is entered.
0011
Set Fail
Pre-set time after the start of the exit time, if the
exit procedure is not complete.
At code entry to reset.
0012
Entry Deviation
When a deviation from the entry route occurs
(during entry time).
At code entry to unset.
0013
Secure Intruder Any
At alarm, after exit time started, until unset.
At the first valid code entry and at end of
confirm time.
0014
Siren Any
When the alarm is live.
When the alarm is silenced or when the siren
timer expires.
0016
Strobe Any
When the alarm is live.
When the alarm is silenced or when the siren
timer expires.
0017
Omit Rearm Any
Input omitted if active (or in alarm condition) at
the end of the confirmation time.
When the system is unset.
0018
Unconfirmed Any
At any intruder of tamper alarm.
At code entry to silence.
0019
Can Set All
When all inputs but the ‘Entry Delay’ and ‘Follow’
inputs are closed.
If fault exists, and after final set.
0020
Exit Starts All
At the start of the exit time to set the LAST area.
At unset FIRST area (such as no longer fully
set).
0021
Exit Starts Any
When the exit time starts to set the FIRST area.
At code entry to unset LAST area.
0022
Final Set Any
When ANY area has been set.
At code entry to unset LAST area.
0023
Strobe Set Fail
Works similar to output 016, but also fires if the ‘set fail’ timer expires.
0025
Keyswitch Unset
This output turns on for five seconds when the system is disarmed via a key-switch input (pulsed
or latched).
0026
Set with Omit
Active when the system is set with an input omitted.
0028
Power Fault
Active during low volts and battery faults. Restores at code entry after the fault is cleared.
0029
Confirm Intruder Any
When more than one intruder alarm activates.
At next code entry.
0030
Confirm HU Any
When more than one confirmed HU activates.
At the next code entry.
0031
Entry
Active during any entry time.
0032
Exit
Active during any exit time.
0033
Entry / Exit
Active during any entry or exit time.