DS-76xx-I2/xP/4S NVR UM
107
1)
Go to
System
>
Event
>
Smart Event
.
2)
Click
Region Exiting
.
Figure 12-7 Region Exiting Detection
3)
Select a
Camera
to configure.
4)
Check
Enable Region Exiting Detection
.
5)
Optionally, check
Save VCA Picture
to save the captured pictures of region exiting detection.
6)
Select
Target Detection
as
Human Body
or
Vehicle
.
Human Body
: Discard non-human body pictures and videos which are not triggered by
region exiting detection.
Vehicle
: Discard non-vehicle pictures and videos which are not triggered by region exiting
detection.
7)
Follow the steps to set the detection rules and detection areas.
1)
Select an Arming Region to configure. Up to 4 regions are selectable.
2)
Drag the sliders to set Sensitivity.
Sensitivity:
The higher the value is, the more easily the detection alarm can be
triggered. Its range is [0-100].
3)
Click Draw Region and draw a quadrilateral in the preview window by specifying four
vertexes of the detection region.
8)
Set the arming schedule. Refer to
Chapter 11.1 Configure Arming Schedule.
9)
Set the linkage actions. Refer to
Chapter 11.2 Configure Alarm Linkage Actions.
10)
Click
Apply
.