Chapter 3 Servicing Your Cyberlight 3-15
3
Replacing Parts
This section explains how to remove and replace parts inside the fixture. Make note of the
following caution and warnings:
Caution
Equipment surfaces may reach temperatures up to 62° C (144° F). Allow
10 minutes for cooling before handling.
Warnings (1) An unshielded MSR/MSD 1200 lamp emits ultraviolet and visible
(UV-vis) radiation which could damage eyes and skin. Never look
directly at the lamp while lamp is on.
(2) Hot lamp may be an explosion hazard. Do not open for 5 minutes
after switching off. Wear eye and hand protection when re-lamping.
(3) Replace fuses only with the specified type and rating.
(4) Disconnect power before re-lamping or servicing.
After allowing the fixture to cool as described above, turn it OFF and unplug it from its power
source. Then see one of the following sections:
•
“Replacing Power Supply Fuses” on page 3-15
•
“Removing and Installing Rotating Lithos” on page 3-19
•
“Replacing Dichroics/Lithos in the Color Wheel or the Static Litho Wheel” on page 3-22
•
“Adjusting the Mechanical Zoom Lens (CX Only)” on page 3-23
•
“Adjusting the Mirror Head Deviation” on page 3-24
•
“Adjusting the Yoke Deviation” on page 3-26
Replacing Power Supply Fuses
This section explains how to replace the four fuses located on the Cyberlight power supply board.
You will need:
- 5/32 inch allen wrench
- Replacement fuses (5 mm by 20 mm only).
There are a total of four:
Amps
Volts
Fuse Type
2.5 A
250 V
Slow Blow Only
4 A
250 V
Fast Blow Only
0.5 A
250 V
Fast Blow Only
1.6 A
250 V
Fast Blow Only
Содержание Cyberlight