1-18
Cyberlight
User Manual
Resetting the Information Counter
The information counter tracks the cumulative length of time (in hours) the lamp has been on and
the number of lamp strikes (the number of times the lamp has been illuminated). To reset the
counter after changing the MSR lamp, perform the following steps:
1.
Turn the fixture power OFF (refer to Figure 1-21).
2.
Set personality switches 3, 4, and 5 ON.
3.
Note the current settings of all address switches, then set all address switches OFF, except for
switch 6. Address switch 6 must be set ON.
4.
Turn the fixture power ON (the fixture will not home).
5.
Set personality switches 3, 4, 5, and address switch 6 (from Step 3) OFF.
6.
Return the address switches to their previous settings.
Optimizing the Cyberlight Fixture Lamp
Caution
Never operate the Cyberlight fixture without first optimizing the lamp.
Damage to the fixture can occur if the lamp is misaligned.
In order to get optimal light output you need to position the lamp’s arc at the focal point of the
fixture’s reflector (i.e., optimize the lamp). You can do this by following the procedure below:
1.
Make sure the fixture’s power switch is OFF (see the section titled “Setting the Cyberlight
Power Switch” on page 1-29). Then plug the fixture’s power cord into the electrical outlet.
2.
Place the Cyberlight in “setup” mode by setting personality DIP switch 2 ON as shown in
Figure 1-13. Make sure that all the remaining personality DIP switches are OFF.
Figure 1-13. Placing Cyberlight fixture in setup mode allows you to perform the
necessary lamp optimization prior to using a newly-installed lamp.
3.
Turn the fixture power ON. The fixture homes before striking the lamp. During the homing
operation you will hear clattering sounds as the wheels, shutter, and mirror seek their home
positions. This is normal. (If the lamp fails to strike, make sure personality switch 2 is set
ON.)
4.
Point the beam at a flat surface several feet away and make sure the beam has a round shape
(not an oval) by following the suggestions below. (If a perfectly flat surface is not available,
point the beam at the flattest surface you can find.)
Set switch 2
ON; all other
On
Off
switches OFF
1
2 3 4 5
6
7 8
p
ers
o
nal
it
y
Содержание Cyberlight