3-10
Cyberlight
User Manual
Figure 3-12. Position the keyhole slots so they fit over both hex screws as well as the
“slider” screw inset in the hub.
9.
Retighten the two screws that hold the wheel in place. Tighten the screws only until they are
snug; do not overtighten.
10. Re-install the standoff you removed in Step 1 on page 3-7.
Cleaning the Infrared Filter, Reflector, Color Mixing Flags and Dim Flags
You will need:
- one right angle 5/32 inch allen wrench
This section explains how to clean two components located inside the Cyberlight lamp box: the
infrared filter and reflector. It also explains how to clean the color mixing flags and the dim flags,
which are located on the other side of the lamp assembly.
Cautions
(1) Equipment surfaces may reach temperatures up to 62° C (144° F).
Allow 10 minutes for cooling before handling.
(2) Change shields, lenses, or the infrared filter if they have become
visibly damaged to such an extent that their effectiveness is impaired, for
example by cracks or deep scratches.
Warnings (1) An unshielded MSR/MSD 1200 lamp emits ultraviolet and visible
(UV-vis) radiation which could damage eyes and skin. Never look
directly at the lamp while lamp is on.
(2) Hot lamp may be an explosion hazard. Do not open for 5 minutes
after switching off. Wear eye and hand protection when re-lamping.
1.
Allow the fixture to cool as described above then
power it OFF and unplug it from the power
source.
Содержание Cyberlight
Страница 123: ...C 8 Cyberlight User Manual...