![Heylo KT 20 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/heylo/kt-20/kt-20_translation-of-the-original-instruction-manual_2128334040.webp)
Condensation dryer KT 20
38 / 48
EN
Safety instructions on faults
DANGER
Danger to life due to electric shock
Touching electrically live parts can be fatal.
a)
Switch off the device and pull out the mains
plug.
CAUTION
Danger due to missing safety covers
Missing safety covers can lead to injuries.
a)
Before switching on the device, install all the
safety covers that may have been removed for
troubleshooting purposes.
b)
Check all the safety devices before switching
on the device.
17.1
Restarting after an unscheduled
downtime
Power failure
After a power failure, the device will continue to op-
erate in continuous operating mode with the device
switch turned on.
17.2
Malfunctions during operation
Malfunction Possible cause
Remedy
The device
is not run-
ning
No or incorrect
power supply
Check the power
cable and the
mains connection.
Target humidity is
set too high (with
built-in hygrostat)
Check the setting
of the target hu-
midity
No con-
densate
Filter is clogged
Check the filters,
replace them if
Malfunction Possible cause
Remedy
forms alt-
hough the
fan is run-
ning
necessary
Fault on the eva-
porator
Contact the
HEYLO technical
staff
Pump is defective Contact the
HEYLO technical
staff
Pump sump is
clogged
See
Cleaning the
pump sump [
41]
Humidity or tem-
perature in the
room is too low
Check the Indoor
climate with a
thermo-hygrometer
The device
is noisy and
vibrates,
condensate
escapes
Device is not level
and upright
Check the operat-
ing conditions,
particularly the
installation site
The device
warms up,
becomes
noisy and
dehumidi-
fies poorly
Disturbed air circu-
lation
Ensure that the air
can circulate freely.
Clean the air slits
in the protective
cover. Check the
air filter.
Tab. 10:
Table of malfunctions
18
Cleaning the device and
maintaining the filter
The following principles apply when cleaning and
maintaining the device:
These tasks may only be carried out by trained and
authorized specialists.
a)
Switch off the device before starting work and
pull out the mains plug.
b)
Wear suitable personal protective equipment.