Maintenance schedule
11
75
11.3
Annually inspection
Annual inspection, at least every 3000 operating hours
Item
Procedure
Maintenance
Conduct system maintenance by authorised
personnel.
Drives and
motors
Check
gear
motor
for
abnormal
or
conspicuous running noises by using the
aggregate test.
Check gear motor visually for damages and
wear.
ID-fan
Unscrew 4x wing nut
Remove and clean ID-fan witch a brush
11.4
As needed
Item
Procedure
Chimney
Maintenance
respectively
Cleaning
and
inspection according to national standards
Item
Procedure
Sensor barrier
Clean sensors on the inside of the
intermediate hopper with soft tissue on
the left and right
Ash storage
Ash has to be stored in a non flammable,
air tight container till disposal.
Boiler room
Remove flammable materials, except
wood chips or pellets stored in a
appropriate container, from the operating
room
Fire protection
Check structural fire protection and fire
doors (e.g.: self-locking fire door)
Содержание firestar de Luxe 18
Страница 1: ...OPERATING INSTRUCTIONS Log wood boiler firestar de Luxe 18 40 ...
Страница 18: ...8 Temperature manager 18 Fig 8 6 Example temperature manager when time mode without difference ...
Страница 80: ...16 Annex 80 16 ANNEX 16 1 Additional boiler module Hydraulic recommendation 1 ...
Страница 81: ...Annex 16 81 Hydraulic recommendation 2 ...
Страница 82: ...16 Annex 82 16 2 Solar module Program 1 ...
Страница 83: ...Annex 16 83 Program 2 ...
Страница 84: ...16 Annex 84 Program 3 ...
Страница 85: ...Annex 16 85 Program 4 ...
Страница 86: ...16 Annex 86 Program 5 ...
Страница 87: ...Annex 16 87 Program 6 ...
Страница 88: ...17 Notes 88 17 NOTES ...
Страница 89: ...Notes 17 89 ...