9
Boiler control
40
Term
Description
Unit
Active Heating time
mode
Indicates the actual operating mode
-
Remote control
number
Display of the selected remote controller
-
Balancing room
sensor
Setting the value (-5 to +5) for calibrating the room sensor
-
Kneeling barrier over
room temperature
Activates the kneeling barrier over the room temperature
-
Barrier over room
temperature
Activates the barrier over the room temperature
-
Settings 2
1
2
3
Room set temperature
Setting up required room temperature (15-30).
°C
Kneeling temperature
Setting up required room temperature (10-22) during lowering time.
°C
Flow fixed
temperature
Setting up the flow temperature (20 to maximum flow set temperature)
during the set heating time (operation mode “flow fixed”)
°C
Room influence
Setting up the factor (0-10) of the room temperature influence.
-
Correction
The correction is a factor for influencing or correction of the flow must
temperature:
▪
This value (-5 to +5) gets multiplied by 2 and added to the flow set
temperature
°C
Kneeling influence
Setting up the factor (0-10) of the kneeling temperature influence.
-
Settings 3
1 2
3
Switching temperature
Setting up the switching temperature (10-35). That´s the average daytime
temperature that conducts the switching between summer mode and
winter mode. The higher the value of the switching temperature is set, the
later the changeover to summer operation is carried out.
°C
Balancing outside
sensor
Adjusting the balancing of the outside temperature sensor (-5 - 5)
▪
Adjustment of the outside temperature sensor to the actual measured
outside temperature (e.g .: with reference thermometer)
°C
Hot water tank priority
Activate hot water tank priority (ON/OFF)
▪
The hot water tank is loaded prior compared to the heating circuit.
-
Kneeling barrier
Activation kneeling barrier (ON/OFF)
▪
The heating circuit is blocked in the case of durable kneeling or outside
the heating time.
-
Menu "Aggregate-Test"
Agg-Test
1
Heating circuit pump*
Indicates the state of the heating circuit pump:
▪
If the indicator lamp lights up, the heating circuit pump is running
-
Heating circuit mixer
OPEN*
Indicates the state of the heating circuit mixer:
If the indicator lamp lights up, the heating circuit mixer is open
-
Heating circuit mixer
CLOSE*
Indicates the state of the heating circuit mixer:
If the indicator lamp lights up, the heating circuit mixer is closed
-
Menu "Time program / Barrier times"
Time program
1 2 3
Содержание firestar de Luxe 18
Страница 1: ...OPERATING INSTRUCTIONS Log wood boiler firestar de Luxe 18 40 ...
Страница 18: ...8 Temperature manager 18 Fig 8 6 Example temperature manager when time mode without difference ...
Страница 80: ...16 Annex 80 16 ANNEX 16 1 Additional boiler module Hydraulic recommendation 1 ...
Страница 81: ...Annex 16 81 Hydraulic recommendation 2 ...
Страница 82: ...16 Annex 82 16 2 Solar module Program 1 ...
Страница 83: ...Annex 16 83 Program 2 ...
Страница 84: ...16 Annex 84 Program 3 ...
Страница 85: ...Annex 16 85 Program 4 ...
Страница 86: ...16 Annex 86 Program 5 ...
Страница 87: ...Annex 16 87 Program 6 ...
Страница 88: ...17 Notes 88 17 NOTES ...
Страница 89: ...Notes 17 89 ...