9
Boiler control
32
Term
Description
Unit
Status 3
1 2
3
Primary air flap
Indicates the state of the primary air flap
%
Secondary air flap
Indicates the state of the secondary air flap
%
O2 [%]
Display of the actual O2-content (oxygen content) in the flue gas
%
CO2 [%]
Display of the actual CO2-content (carbon dioxide content) in the flue gas
%
Menu
„Settings“
Settings
1
Boiler max
temperature
Setting the temperature for the end of control (The system goes into the
ready mode)
°C
Boiler must
temperature
Setting the temperature for the start of control
°C
Buffer difference
Setting the difference between the boiler temperature and the actual
buffer bottom temperature for controlling the return pump
°C
Menu
"inputs / outputs" (system-specific)
In-/Outputs
1
2
Back flow pump
Displays the state of the backflow pump:
If switch on green
➔
Output active.
-
Back flow mixer open
Displays the state of the Backflow mixer:
If switch on green
➔
Output active.
-
Back flow mixer close
Displays the state of the Backflow mixer:
If switch on green
➔
Output active.
-
Safety temperature
limiter (STL)
Indicates the input of the safety temperature limiter (STL): If the indicator
lamp lights up, the STL has tripped.
-
Door opened
Display of the status of the door: If the control lamp lights up, the door
input has triggered.
-
Sum annoyance
Displays the condition of the Sum annoyance:
If switch on green
➔
Output active (active fault).
-
In-/Outputs
1
2
Lambda heating
Indicates the state of the lambda probe heating.
If switch on green
➔
Output active.
%
ID fan
Display of the output of the ID-fan control and display of the currently
measured speed.
%
Primary air flap
Indication of the primary air flap control output
%
Secondary air flap
Indication of the secondary air flap control output
%
Heat exchanger
cleaning (HEC)
Indicates the state of the HEC system:
If switch on green
➔
Output active
-
Heatexchanger
cleaning (HEC)
monitoring
Indicates the state of the sensor of the HEC- monitoring.
If the indicator lamp lights up alternately during operation, the HEC works
correct.
.
Menu
„Operating hours“
Operating hours
1
2
Nominal load
Displays system operation hours during nominal load phase (95 -100%)
h
Modulation
Displays system operation hours during modulation phase (94-31%)
h
Содержание firestar de Luxe 18
Страница 1: ...OPERATING INSTRUCTIONS Log wood boiler firestar de Luxe 18 40 ...
Страница 18: ...8 Temperature manager 18 Fig 8 6 Example temperature manager when time mode without difference ...
Страница 80: ...16 Annex 80 16 ANNEX 16 1 Additional boiler module Hydraulic recommendation 1 ...
Страница 81: ...Annex 16 81 Hydraulic recommendation 2 ...
Страница 82: ...16 Annex 82 16 2 Solar module Program 1 ...
Страница 83: ...Annex 16 83 Program 2 ...
Страница 84: ...16 Annex 84 Program 3 ...
Страница 85: ...Annex 16 85 Program 4 ...
Страница 86: ...16 Annex 86 Program 5 ...
Страница 87: ...Annex 16 87 Program 6 ...
Страница 88: ...17 Notes 88 17 NOTES ...
Страница 89: ...Notes 17 89 ...