Warning notes
6
2.2.2
Operation
General safety instructions
Covers which prevent contact
with hot or rotating parts or which
are required in order to direct the
flow of air correctly and thus
ensure the effective functioning of
the system must not be opened
during operation.
In the event of a fault or unusual
operating conditions such as the
emission of smoke or flames, the
system is to be switched off
immediately by operating the
emergency stop button. Notify the
HERZ
Customer
Service
department immediately.
◼
If the boiler room door main switch is
operated or if a power failure occurs, the
system will be taken out of operation
immediately. The remaining quantity of
residual fuel will burn independently
without giving off any toxic gases provided
that the chimney draught is sufficiently
high. Therefore, the chimney must be
designed and produced in accordance
with DIN 18160 or EN 13384. When the
boiler is switched on again, the system
has to be checked in order to make sure
that it is fully functional and a safe
operation of the whole system must be
guaranteed!
◼
If the residual flue gas oxygen content
drops below the required minimum of 5
%, the fuel supply will be stopped
automatically and will not be activated
again until the residual oxygen content
has risen to more than 5 % (fault text:
MIN O2 [%] 5.0, see chapter boiler Status
IV)
◼
The generated system noise during
operation does not present any danger to
the operator´s health.
2.2.3
Maintenance
General safety measures
Before starting to carry out any work on the
system, but especially before opening covers
protecting live parts, the system is to be properly
disconnected from the power supply. Besides the
main circuits, attention is also to be paid to any
existing additional or auxiliary circuits in the
process. The normal safety rules according to
ÖNORM are:
◼
Disconnect all poles and all sides!
◼
Ensure that the system cannot be
switched on again!
◼
Check to ensure that no voltage is
connected!
◼
Earth and short-circuit!
◼
Cover adjacent live parts and locate
hazardous areas
These
above-mentioned
measures must not be reversed
until the system has been fully
installed and maintenance has
been completed.
Personal dust masks and gloves
must be worn when carrying out
maintenance in the combustion
chamber or the ash collector or on
flue gas-carrying parts and when
emptying the ash container, etc.!
Extra-low-voltage lamps are to be
used
when
carrying
out
maintenance work in the storage
room. Electrical equipment in the
storage room must be designed in
accordance
with
ÖNORM_EN_ISO_20023!
In order to prevent any maintenance errors, if
maintenance is not carried out properly, it is
recommended to be carried out regularly by
authorised personnel or by the HERZ Customer
Service department.
Spare parts must be obtained directly from the
manufacturer or a distribution partner. The
customer will not be exposed to any health risks
as a result of the noise generated by the machine.
Содержание firestar de Luxe 18
Страница 1: ...OPERATING INSTRUCTIONS Log wood boiler firestar de Luxe 18 40 ...
Страница 18: ...8 Temperature manager 18 Fig 8 6 Example temperature manager when time mode without difference ...
Страница 80: ...16 Annex 80 16 ANNEX 16 1 Additional boiler module Hydraulic recommendation 1 ...
Страница 81: ...Annex 16 81 Hydraulic recommendation 2 ...
Страница 82: ...16 Annex 82 16 2 Solar module Program 1 ...
Страница 83: ...Annex 16 83 Program 2 ...
Страница 84: ...16 Annex 84 Program 3 ...
Страница 85: ...Annex 16 85 Program 4 ...
Страница 86: ...16 Annex 86 Program 5 ...
Страница 87: ...Annex 16 87 Program 6 ...
Страница 88: ...17 Notes 88 17 NOTES ...
Страница 89: ...Notes 17 89 ...