72
Display
Cause
Panel Board Correction
“E-48”
Input system
error.
Have PC board replaced.
“E-54C”
Temperature in-
put error.
Turn power switch to off, then back to on; have control PC
board replaced if “E-54C” persists.
“E-60”
AIF PC board not
communicating
with PC board.
Turn power switch to off, wait 15 seconds, then turn switch
back to on. If “E-60 persists, have connector between the
PC boards checked; replace AIF PC board or control PC
board if necessary.
“E-70C”
Drain valve jump-
er wire missing or
disconnected.
Have the jumper wire checked on the PC board at drain
switch interlock position.
“E-83-A”
Pressure too
high.
Check filter system in vat #1
“E-83-B”
Pressure too
high.
Check filter system in vat #2
“E-83-C”
Pressure too
high.
Check filter system in vat #3
“E-83-D”
Pressure too
high.
Check filter system in vat #4
“E-83-E”
Pressure too
high.
Check filter system in vat #5
“E-83-J”
Bulk BIB fill
switch on when
pressure too
high.
Check BIB fill valves
“E-83-R”
Bulk dispose
switch on when
pressure too
high.
Check Bulk Dispose quick-disconnect behind fryer.
“E-93-1”
”24 VDC
SUPPLY
TRIPPED”
Autolift motor
malfunction or
failure.
If AutoLift feature is not operating, have each of the Auto-
lift motors checked.
Содержание Wendy's Evolution Elite EEG-251
Страница 2: ......
Страница 5: ...Contents iii...
Страница 14: ...Introduction 2...
Страница 19: ...Installation 7 Figure 2 1 Flexible Gas Line Cable Restraint Installation...
Страница 22: ...Figure 2 2 1 Well Dimensions Figure 2 3 2 Well Dimensions Installation 10...
Страница 23: ...Figure 2 4 3 Well Dimensions Figure 2 5 4 Well Dimensions Installation 11...
Страница 24: ...Installation 12...
Страница 51: ...Operation 37...
Страница 62: ...Operation 48...
Страница 68: ...Information Mode 54...
Страница 72: ...Product Program Mode 58...
Страница 87: ...Troubleshooting 73...
Страница 88: ...Troubleshooting 74...
Страница 89: ...blank page...