71
Display
Cause
Panel Board Correction
“E-15”
Drain switch.
Make sure drain knob is completely pushed-in; if “E-15”
persists, have drain switch checked.
“E-18A”
Left level sensor
open.
Turn switch to off position, then back to on; if display still
indicates a failed sensor, have the connections checked
on the control board. Have sensor check and replaced if
necessary.
“E-18B”
Right level sen-
sor open.
“E-18C”
Both level sen-
sors open.
“E-20-A”
”FAN SEN-
SOR
STUCK
CLOSED”
Pressure switch
failure.
If fan is not running, have pressure switch checked;
should be open circuit if no air pressure.
Wiring problem.
If fan is running, wiring error, or relay on I/O board closed.
I/O board failure.
“E-20-B”
”NO
DRAFT”
“CHECK
FAN”
Pressure switch
failure/hose
loose.
Press power button to vat off and back on again; if “E-20-
B” persists, have pressure switch checked; should be
open circuit if no air pressure; make sure hose is con-
nected to fan and pressure switch.
Draft fan failure/
low voltage.
Have draft fan checked; low voltage going to fan.
Flue or hood
obstruction.
Check the fryer flue and hood system for obstruction.
“E-20-D”
”IGNITION
FAILURE”
Failure to ignite/
no flame sense.
Press power button to vat off and back on again, if “E-20-
D” persists, check gas line connections; check gas shutoff
valve; have ignition module checked; gas valve checked;
flame sensor gap checked; gas valve and ignition module
wiring checked.
“E-21”
Slow heat
recovery.
Have a certified service technician check the fryer for cor-
rect voltage to the unit; have heat circuit checked; have
unit checked for loose or burnt wires.
“E-22”
”NO HEAT”
”CHECK
GAS
VALVE”
Burner not
igniting.
Have gas valve and heat circuit checked.
“E-41”
”E-46”
Programming
failure.
Turn power switch to off, then back to on; if display shows
an error code, have the controls re-initialized; if error code
persists, have the control board replaced.
“E-47”
Analog converter
chip or 12-volt
supply failure.
Turn power switch off, then back to on; if “E-47” persists,
have the I/O board, or the PC board replaced; if speaker
tones are quiet, probably I/O board failure; have the I/O
board replaced.
Содержание Wendy's Evolution Elite EEG-251
Страница 2: ......
Страница 5: ...Contents iii...
Страница 14: ...Introduction 2...
Страница 19: ...Installation 7 Figure 2 1 Flexible Gas Line Cable Restraint Installation...
Страница 22: ...Figure 2 2 1 Well Dimensions Figure 2 3 2 Well Dimensions Installation 10...
Страница 23: ...Figure 2 4 3 Well Dimensions Figure 2 5 4 Well Dimensions Installation 11...
Страница 24: ...Installation 12...
Страница 51: ...Operation 37...
Страница 62: ...Operation 48...
Страница 68: ...Information Mode 54...
Страница 72: ...Product Program Mode 58...
Страница 87: ...Troubleshooting 73...
Страница 88: ...Troubleshooting 74...
Страница 89: ...blank page...