70
Problem
Cause
Correction
Bubbles in
oil during
entire filter-
ing
process.
Filter pan not
completely
engaged.
Make sure filter pan return line is pushed completely into
the receiver on the fryer.
Filter pan
clogged.
Clean pan and change paper or pad.
Damaged O-ring
on filter line re-
ceiver on fryer.
Replace O-ring.
Filter motor
will not run.
Power cord for
vat #1 is not
plugged in.
Plug power cord into receptacle.
Open circuit.
Breakers in fryer tripped; open left door and reset breaker
on fryer.
Thermal reset
button on the rear
of the pump mo-
tor is tripped.
Allow motor to cool, then, using a screwdriver, press hard
against the button until it clicks.
T
To
o
p
prre
evve
en
ntt
b
bu
urrn
nss
cca
au
usse
ed
d
b
byy
ssp
plla
assh
hiin
ng
g
ssh
ho
orrtte
en
niin
ng
g,, ttu
urrn
n tth
he
e u
un
niitt’’ss p
po
ow
we
err ssw
wiittcch
h tto
o tth
he
e o
offff
p
po
ossiittiio
on
n b
be
effo
orre
e rre
esse
ettttiin
ng
g tth
he
e ffiilltte
err p
pu
um
mp
p m
mo
otto
orr’’ss
m
ma
an
nu
ua
all rre
esse
ett p
prro
otte
eccttiio
on
n d
de
evviicce
e..
7
7..2
2 E
Errrro
orr C
Co
od
de
ess
In the event of a control system failure, the digital display shows an error message.
The message codes are shown in the display column below. A constant tone is heard
when an error code is displayed, and to silence this tone, press any button.
T
Ta
ab
blle
e 7
7--2
2 E
Errrro
orr C
Co
od
de
ess
Display
Cause
Panel Board Correction
“E-4”
Control board
overheating.
Turn switch to off position, then turn switch back to on; if
display shows “E-4”, the control board is getting too hot;
check the louvers on each side of the unit for obstruction.
“E-5”
Oil overheating.
Turn switch to off position, then back to on; if display
shows “E-5”, the heating circuits and temperature probe
should be checked.
“E-6A”
Temperature
probe open.
Turn switch to off position, then back to on; if the display
shows “E-6”, the temperature probe should be checked.
“E-6B”
Temperature
probe shorted.
“E-10”
High limit.
Let the unit cool down (15-20 minutes), push up on metal
reset button under right side of the controls; if high limit
does not reset, high limit must be replaced.
Содержание Wendy's Evolution Elite EEG-251
Страница 2: ......
Страница 5: ...Contents iii...
Страница 14: ...Introduction 2...
Страница 19: ...Installation 7 Figure 2 1 Flexible Gas Line Cable Restraint Installation...
Страница 22: ...Figure 2 2 1 Well Dimensions Figure 2 3 2 Well Dimensions Installation 10...
Страница 23: ...Figure 2 4 3 Well Dimensions Figure 2 5 4 Well Dimensions Installation 11...
Страница 24: ...Installation 12...
Страница 51: ...Operation 37...
Страница 62: ...Operation 48...
Страница 68: ...Information Mode 54...
Страница 72: ...Product Program Mode 58...
Страница 87: ...Troubleshooting 73...
Страница 88: ...Troubleshooting 74...
Страница 89: ...blank page...