MALFUNCTION ANALYSIS
10-2
MSHF • 7295-026A
In all cases not covered by the above malfunction tables an electrician must be
consulted.
No power supply
- Defective fuses in building site supply
- Damaged cable
- Motor safety relais switched off
- Main switch defective
Voltage too low
- Incorrect cable type
- Cable is too long
Motor does not run
42 Vac control voltage
not present
- Automatic fuses operated
Voltage present but
platform cannot be raised or
lowered
Relays K102 en K103 are
energized but platform
does not move up or
down
- Motor brake locked
- Adjust brake
Brake distance too long
- Wrong adjusting parralel movement
protection
- Adjust brake
The platform decends
erratically
- Minimum mast distance too little
Other malfunctions
The platform does not
develop sufficient power
- Inform your technical service or dealer