ASSEMBLY AND ANCHORING
6-4
MSHF • 7295-026A
6.3
Positioning the mast climbing
work platform
A fence (height 1.10 m / 43.3 in)
completely surrounding the
platform is compulsory. If the
distance between the platform
and the facade is 0.3 m - 0.5 m /
11.8 in - 19.7 in a fence with a
height of 0.7 m / 27.6 in can be
used. If the distance between the
platform and the facade is less
than 0.3 m / 11.8 in a fence is not
compulsory but in this case a
kick board with an height of
0,15m / 5.9 in must be fitted.
Wheels of the chassis should not
have a bearing function while
assembly and operating the
platform.
Distance to the facade with standard
anchoring.
A = 575 - 1300 mm / 22.6 - 51.2 in
B = 550 - 1275 mm / 21.7 - 50.2 in
C = 25 mm / 1 in
There are four ways in which the mast
climbing work platform can be placed:
- single mast, freestanding (chassis
mounted)
- single mast, anchored (chassis or
ground frame mounted)
- two masts, freestanding (chassis
mounted)
- two masts, anchored (chassis or ground
frame mounted).
Fig.6-4
Distance to the facade
Содержание MSHF
Страница 1: ...7295 026A Issue 02 2000 USER S MANUAL MSHF MAST CLIMBING WORK PLATFORM This manual is assigned to...
Страница 4: ...IV MSHF 7295 026A...
Страница 10: ...X MSHF 7295 026A Fig 1 Dimensions...
Страница 14: ...TECHNICAL DETAILS 1 4 MSHF 7295 026A Fig 1 6 Drive unit...
Страница 16: ...TECHNICAL DETAILS 1 6 MSHF 7295 026A Fig 1 7 Chassis Fig 1 8 Ground frame...
Страница 30: ...SAFETY 3 4 MSHF 7295 026A...
Страница 70: ...DISASSEMBLY AND TRANSPORT 8 4 MSHF 7295 026A...
Страница 80: ...MACHINE DISPOSAL 11 2 MSHF 7295 026A...
Страница 83: ...APPENDICES 1 MSHF 7295 026A...
Страница 84: ...APPENDICES 2 MSHF 7295 026A...