![HEIDELBERG Speedmaster CD 102 Скачать руководство пользователя страница 158](http://html1.mh-extra.com/html/heidelberg/speedmaster-cd-102/speedmaster-cd-102_manual_2118608158.webp)
GR FS9040012000000000
GR FS9040013000000000
Maintenance
confidential
D.3.14
5.4
Capacitive sensor ”Automatic pile transport changeover”
1
Fig. 16
Place of installation of the ”Automatic
pile transport changeover” sensor
Place of installation
1
Capacitive sensor ”Automatic pile transport
changeover”
The capacitive sensor ”Automatic pile transport
changeover” is installed at the end of the feed table,
before the pile.
5.4.1
Cleaning the capacitive sensor
1
Fig. 17
Clean the sensor
1
Capacitive sensor ”Automatic pile transport
changeover”
Maintenance point description
Maintenance inter-
val
15 000 000 prints, or twice a
year
Maintenance loca-
tion
Center
Accessibility of the
maintenance points
Remove the pile from the
feeder. Secure the press
against start-up.
Number/type/main-
tenance work
Clean the sensor.
Tool
Clean, fluffless cloth; brush
Cleaning solution
See ”Approved cleaners”.
Tab. 10
UTKFS9040004000000000008
Содержание Speedmaster CD 102
Страница 6: ...Main chapter overview A 2...
Страница 20: ...Main chapter overview B 2...
Страница 114: ...Preset Plus Feeder confidential C 1 76...
Страница 118: ...Main chapter overview D 4...
Страница 120: ...Chapter overview D 1 2...
Страница 134: ...General information confidential D 1 16...
Страница 136: ...Chapter overview D 2 2...
Страница 146: ...Chapter overview D 3 2...
Страница 166: ...Maintenance confidential D 3 22...
Страница 170: ...Index E 4 V VISCOGEN KL 300 Lubricant of the central grease lubrication D 1 10 W Washing fluid D 1 14...