GR SG9015861000000000
GR SG9015862000000000
GR SG9015864000000000
Preset Plus Feeder
confidential
C.1.66
1
2
Fig. 86
Detaching the pneumatic cylinder of the breather
11.
Loosen the retaining spring (Fig. 86/1) at the
pneumatic cylinder of the breather (Fig. 86/2).
12. Detach the pneumatic cylinder.
1
Fig. 87
Removing the suction tape module
13. Four screws secure the suction tape module on
the feeder frame.
Loosen the four screws (Fig. 87/1).
Note
The suction tape module is heavy. Do
not carry the suction tape module on
your own. Ask another person to help
you.
14. Together with a second person, raise the suc-
tion tape module from the feeder.
Place the suction tape module onto a stable
support.
19.3 Removing the suction tape
1
Fig. 88
Clamp bolt on the suction tape module
1.
Turn the clamp bolt (Fig. 88/1) anti-clockwise in
order to relieve the suction tape.