
6 Using the heating system – ON/OFF menu
82
HDG Compact 99 - 200 - Version 1 - en
©
HDG Bavaria GmbH 07/2008
A
CTIVATING
THE
FUNCTION
“L
AMBDA
S
TOP
”
If the specified minimum residual oxygen value is not met, the fuel
feeding is interrupted until the residual oxygen values are again
within the acceptable range.
✎
See “Procedure” in this section.
✎
For the setting of the minimum lambda value, see section “6.7 °C/
QUANTITY menu”, paragraph “Entering the residual oxygen set-
ting”.
A
DJUSTING
THE
ASH
REMOVAL
SETTING
The movement of the stepping grate and the ash removal system
can be switched off.
✎
See “Procedure” in this section.
C
HANGING
THE
CLEANING
SYSTEM
SETTING
The automatic heat exchanger cleaning system can be switched off.
✎
See “Procedure” in this section.
Setting
1-06
Ash removal
: Automatic
CHOOSE
END
The standard setting is
Automatic
.
Setting
1-07
Cleaning system
: On
CHOOSE
END
The standard setting is
On
.
Содержание Compact 100
Страница 1: ...hdg bavaria com HDG Compact 99 200 Operation Manual ...
Страница 2: ......
Страница 162: ...12 Index 162 HDG Compact 100 105 150 200 Version 1 de HDG Bavaria GmbH Juli 2005 NOTICE ...
Страница 163: ......