7 Cleaning and servicing the heating system – Procedure
146
HDG Compact 99 - 200 - Version 1 - en
©
HDG Bavaria GmbH 07/2008
I
NSPECTING
THE
FUEL
BUNKER
1.
Switch the heating system off.
✎
See the chapter entitled “6 Using the heating system”, section “6.3
Switching off the heating system”.
2.
Allow the fire in the heating system to burn out and cool down.
3.
Open the access hatch.
4.
Inspect the fuel bunker for the burning of unsuitable residues or
foreign bodies and remove these if necessary.
5.
Close the access hatch.
6.
Switch the heating system on again.
✎
See the chapter entitled “6 Using the heating system”, section “6.2
Switching on the heating system”.
✓
The fuel bunker is cleaned.
Important!
✎
See “Generally applicable safety instructions” in this section.
Caution!
Risk of injury from automatically driven components
When the heating system is turned on, the delivery auger rotates in
the fuel bunker. Hands and feet could thereby be crushed.
Switch the heating system off before you enter the fuel bunker.
Follow the advisories of government safety organisations.