HDG Bavaria GmbH 07/2008
HDG Compact 99 - 200 - Version 1 - en
6 Using the heating system – Calling up information, selecting and modifying parameters
75
6.5 Calling up information, selecting and mo-
difying parameters
On the display of the control panel for the HDG Control, you can call
up various information as well as select and modify parameters.
Due the freely programmable design and the numerous options in
heating system combinations, especially in regard to the extraction
technology, the number of parameters can vary greatly.
S
TANDARD
DISPLAY
The standard display shows you various information, such as opera-
ting status of the heating system, hours of operation, boiler tempera-
ture and the time.
Not enabled
•
The heating system is controlled via an external heating circuit
regulator.
•
There was no enable command from the superordinate heating
circuit regulator.
Lambda stop
•
The residual oxygen value for combustion has fallen below the
minimum.
•
The heating system waits until the minimum residual oxygen
value has been reached again.
Material stop
•
The fill level indicator in the combustion chamber has signalled.
•
There is too much material in the combustion chamber.
•
The heating system waits until the fill level indicator enables fil-
ling again.
Combustion chamber
temperature stop
•
The maximum permitted temperature in the combustion cham-
ber has been exceeded.
•
The heating system waits until the combustion chamber falls back
below the maximum permitted temperature.
Operating status
Description
Table 6/1 - Operating statuses (continuation)
Heating OFF
0.0
hours
Boiler temp.
: 40 °C
15:55
ON
OFF
°C
QUANT
ITY
TIME
MAN.
SERVICE
INFO