Pot Maximum
It sets the max command input. This demands 100% output.
If the command input is > POT M the Command Margin, the evc/epc will declare an error and
the outputs go to the default settings.
Pot Center
– Sets the value of the center of the deadband.
Pot Minimum
It sets the min command value. This demands 0% output.
If the command input is < POT Minimum - the Command Margin, the evc/epc will declare an error and
the outputs go to the default settings.
Reference voltage
is 5V @ 250mA.
HCT has a manual command potentiometer – part number 999-10205 that o0.5V
dc
to +4.5V
dc
when connected to a +5V
dc
user voltage.
Auto Calibrate Pot Input
Calibrate the command limits – i.e. joystick or foot pedal etc.
When the button is clicked, a box will appear with
instructions.
Adjust the input from full High to full Low, then adjust to the
neutral or crossover point.