023-00354-Rev1.4 evc/epc
User
Manual
Copyright © High Country Tek, Inc. – 2013
15
evc/epc
Controller
With
SAE
J1939
Interface
Dashboard
PWM% A/B
– displays the output for coil A
and B in the percent of duty cycle. The PWM% B
will be “Grayed Out” when Coil B is disabled.
% Demand A/B
–
displays the percent of
demand for the output with respect to the
Maximum and Minimum Current settings. The %
Demand B will be “Grayed Out” when Coil B is
disabled.
Coil Current A/B
– displays the output
current. The Coil B Current will be “Grayed Out”
when Coil B is disabled.
Enabled/Disabled
– displays the current state of the enable input connection.
Command Volts/mAmps
– Displays the voltage or current at the Command input - (pin 3).
Reference Volts
– Displays the voltage at the User Reference output - (pin 2).
Supply Volts
– Displays the voltage at the main Power Supply Input - (pin 1).
Average Coil Current
– Applies averaging function to the displayed coil current.
A
A
C
D
D
C
B
B
E
E
F
F
G
G