SupervisorMode
WTX120
A4500-1.1
HBM: public
101
10.2.14
Target weight
This is the target weight of the dosing process. Entering the target weight auto
matically makes the following settings, if they were not already set.
Command
Significance
Setting
CFD
Coarse flow cut-off point
50.0% of target weight
CBK
Coarse flow fill flow monitoring
0 (= off)
FFD
Fine flow cut-off point
95.0% of target weight
FBK
Fine flow fill flow monitoring
0 (= off)
FFM
Minimum fill flow
1.0% of target weight
LTL
Lower tolerance limit
99.8% of target weight
UTL
Upper tolerance limit
100.2% of target weight
SYD
Systematic difference
0 (= off)
10.2.15
Empty weight
For dynamic processes, such as dosing, you should restrict the possible tare
value so as to rule out overfilling. This might happen if there is already material
in the container on starting. If you do not set this tare limit, the coarse flow cut-
off point will be used as the limit.
After starting filling (RUN command or digital input or Enter key), any preset
tare delay is waited and then a check is made whether the weight is below the
specified value for the empty weight. If it is, taring is carried out; otherwise no
new taring is carried out (the old tare value is retained).
Содержание WTX120
Страница 1: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Страница 3: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Страница 184: ...Service password 182 A4500 1 1 HBM public WTX120 ...
Страница 185: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Страница 366: ...Service Passwort 182 A4500 1 1 HBM public WTX120 ...
Страница 367: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Français WTX120 ...
Страница 549: ...Mot de passe de service WTX120 A4500 1 1 HBM public 183 ...