90
Connection
HBM
QuantumX
6.3.2
MX840A status display
The front panel of the universal amplifier has a system LED and 8 connection LEDs. The
system LED indicates the status of the device, the connection LEDS the states of the
individual connections.
System LED
Connection LED
Fig.6.5:
MX840A front view
System LED
Green
Error-free operation
Orange
System is not ready, boot procedure running
Flashing orange
Download active, system is not ready
Red
Error
Connection LEDs
All LEDs are orange
Boot procedure running (system is not ready)
All LEDs are flashing orange
Firmware download active (system is not ready)
Orange
Connection newly assigned, transducer identification running (calibration)
Green
Error-free operation (”Ignore TEDS” or ”if available” set,
channel is manually configured)
Flashing green (5s), then
green
Reading TEDS data
Flashing orange (5s), then
green
Manual configuration running (ignore TEDS)
Red
No sensor connected
Channel error (incorrectly parameterized, connection error, invalid TEDS data)
CAN LEDs
Green
CAN bus activated, CAN data can be received
Orange
CAN bus in ”WARNING” state, CAN data received but bus is occasionally
disturbed; buffer overflow, individual data lost
Red
CAN bus in ”ERROR” or ”BUS-OFF” state, CAN data cannot be received or
processed
General rule:
Brief flashing
→
TEDS identified (green: is used, orange: is not used).
Содержание QuantumX MX1609
Страница 1: ...I3031 8 0 en Operating Manual ...
Страница 2: ...d ...
Страница 31: ...31 Housings HBM QuantumX Fig 4 2 Amplifier MX1609 P in IP65 housing ...
Страница 34: ...34 Housings HBM QuantumX a f 2 5 Fig 4 7 Mounting the CASEPROT ...
Страница 36: ...36 Housings HBM QuantumX Fig 4 10 Attaching the covers ...
Страница 38: ...38 Housings HBM QuantumX Fig 4 13 Close the lever Fig 4 14 Connected housings ...
Страница 99: ...99 Connection HBM QuantumX Connection of the thermocouple plug in the miniature design ...
Страница 144: ......
Страница 180: ...179 Support HBM QuantumX ...