Connecting individual QuantumX modules
5.1
Connecting the supply voltage
Connect the modules to a DC voltage of 10 V ... 30 V (recommended 24 V), see the table for
the power consumption per device.
CAUTION
A rule of thumb for voltage distribution via FireWire says:
”An external supply voltage of equal potential is required at every third module”.
Defects in the device cannot be excluded if a supply voltage > 30 V is used. If the supply
voltage drops below 10 V, the modules switch off.
In the event of battery operation in a vehicle, we recommend incorporating an uninterrupted
voltage supply between battery and module to compensate for voltage drops during starting
processes.
Module
Typical power consumption, including transducer excitation (Watt)
MX840
13
MX840A
12
MX440A
10
MX1601
13
MX410
15
MX460
9
MX1609
6
MX1609-P
6
CX22
12
CX27
7
MX878
7
MX471
6
If several modules are connected to each other via
FireWire
for time
−
synchronous data
acquisition (see Fig.5.4), the supply voltage can be looped through. The power pack used
must be able to provide the appropriate output.
The maximum permissible current on the FireWire connection cable is 1.5 A.If the chain is
longer
repeating the supply connection is mandatory
.
If several amplifiers are operated non
−
synchronously (see Fig.5.3), they must be supplied
separately.
X104
NTX001
1
−
Kab271
−
3
or
X101/X102
1
−
Kab269
FireWire
Fig.5.1:
Connecting socket for supply voltage
Содержание QuantumX MX1609
Страница 1: ...I3031 8 0 en Operating Manual ...
Страница 2: ...d ...
Страница 31: ...31 Housings HBM QuantumX Fig 4 2 Amplifier MX1609 P in IP65 housing ...
Страница 34: ...34 Housings HBM QuantumX a f 2 5 Fig 4 7 Mounting the CASEPROT ...
Страница 36: ...36 Housings HBM QuantumX Fig 4 10 Attaching the covers ...
Страница 38: ...38 Housings HBM QuantumX Fig 4 13 Close the lever Fig 4 14 Connected housings ...
Страница 99: ...99 Connection HBM QuantumX Connection of the thermocouple plug in the miniature design ...
Страница 144: ......
Страница 180: ...179 Support HBM QuantumX ...