4.11. Digital Control Interface Orientation
The Digital Control Interface can be rotated to any of four desired positions after installation by
removing the two screws securing the interface to the motor drive, lifting the interface and rotating it to
the desired position, and replacing the two screws in the new position. (Figure )
Figure 4.11.-1
4.12. Interface Wall Mounting
The interface can also be wall mounted using the parts supplied in the wall mount kit using the
following procedure.
1.
TURN OFF THE ELECTRICAL POWER AT THE CIRCUIT BREAKER.
2.
Loosen the two screws securing the user interface to the motor drive. (Figure 4.12-1)
3.
Disconnect the short cable that extends out from the motor drive. (Figure 4.12-1)
4.
Install the blank cover on the motor drive in the desired orientation. This cover is important to
protect internal electronics. (Figure 4. 13-2)
5.
Mount the wall mount plate in the desired location. (Figure 4.12-3)
6.
Connect the interface cable as shown in the Wall Mounted Digital Control Interface Wiring Diagram
shown in section 5.2 to the motor drive and user interface PCB. Use the multi-conductor, jacketed
cable suitable for the installation location. The cable must be routed through the “DATA” conduit
opening on the motor drive and through the slot provided on the backside of the wall mount plate,
SP3200DR10. Use a liquid tight cord grip that is appropriately sized for the cable being used to seal
the conduit opening. The cable being used may be up to 500 feet in length.
7.
Mount the user interface to the wall mount plate using the two screws. (Figure 4.12-3)
8.
Apply power to the system and resume normal operation.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS