Figure 9.6-1: Removing the Variable Speed Drive
Note:
Motor leads must be disconnected prior to removing drive, and reconnected when new drive is
mounted. Take care to ensure that the motor leads are not pinched between the drive enclosure and the
motor during assembly. The drive mounting screws must be tightened to 30 inch-pounds.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
_____________________________________________________________________________________
Hayward Flow Control
www.haywardflowcontrol.com
1-888-HAY-INDL (1-888-429-4635)
IS3401VSPFC Rev A 12/08/14