6.
+ -
Select whether to display speed in rpm evolutions
per Minute) or % of full speed
< >
Move to next menu item
7.
+ -
Set maximum running speed of pump
< >
Move to next menu item
8.
+ -
Set minimum running speed of pump
< >
Move to next menu item
9.
+ -
Select pump prime mode
< >
Move to next menu item
Note:
User may set the pump to automatically sense when it has reached full prime. User may also set
the pump to prime at the maximum allowed speed for 3 minutes. The 3-minute prime mode should be
used if the maximum allowed speed is set below 3000 rpm.
10.
+ -
Enable or Disable Low Temp Operation
< >
Move to next menu item
11.
+ -
Set pump speed for Low Temp Operation
< >
Move to next menu item
Note:
The pump can be controlled by a Hayward control through the Comm Bus, or by a third party
control using relay contacts to select speeds set in the Timer Menu. When communicating with
Hayward controls other than OmniLogic, a bus address must be chosen for the pump. When
communicating with OmniLogic, the Comm Bus Address screen is not shown and the HUA (Hayward
Unique Address) is used. If Relay Control is selected, the timer speed settings are invoked when inputs
1-3 (INP1-INP3) are selected according to the table in section 5.4.
12.
+ -
Set SVRS Restart to Automatic or Manual
< >
Move to next menu item (not applicable)
13.
+ -
Enable or Disable Low Temp Operation
< >
Move to next menu item
14.
+ -
Set pump speed for Low Temp Operation
< >
Move to next menu item
15.
+ -
Set temperature to activate Low Temp Operation
< >
Move to next menu item
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
_____________________________________________________________________________________
Hayward Flow Control
www.haywardflowcontrol.com
1-888-HAY-INDL (1-888-429-4635)
IS3401VSPFC Rev A 12/08/14
Pg. 23 of 36
Speed Selection
rpm
MAX allowed speed
3250 (600-3450rpm)
MIN allowed speed
600 (600-3450rpm)
Set max-speed Prime
Period: Auto Sense
Low Temp Speed
1000 (600-3450rpm)
Low Temp Operation
Disabled
SVRS Restart
Automatic
Low Temp Speed
1000 (600-3450rpm)
Low Temp Operation
Disabled
Drive Temp Setting
5ºC (41.0ºF)