Note:
When the pump is stopped and the internal motor drive temperature reaches the operation
temperature set point, then the pump will prime and then run according to the set speed until the internal
drive temperature becomes 10° F higher than the temperature set point. The internal drive temperature
does
not
correlate to the ambient outside temperature. Low temperature operation is
not
active when the
pump is being remotely controlled.
Low temperature operation is NOT intended to protect the
pump, system plumbing, or tank from freezing.
If Low Temp Operation is disabled, the speed and
temperature setting screens are not shown.
16.
+ -
Use + to reset to factory default settings
< >
Use > to skip reset
17.
+ -
Confirm reset of all parameters
< >
Move to next menu item
18.
6.7. Timer Menu
Buttons
Screen
Used
Comments
1.
< >
Use > to enter Timer Menu
2.
3.
+ -
Use + to change displayed timer
< >
Use > to skip to next timer
4.
+ -
Use + to rename timer
< >
Use > to set motor speed for timer
5.
+ -
Use to set speed for timer
< >
Use > to set start/stop time
6.
+ -
Use to set start/stop time for timer
< >
Use > to choose days of operation for timer
7.
+ -
Use to choose days of operation for timer
< >
Move to next menu item
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
_____________________________________________________________________________________
Hayward Flow Control
www.haywardflowcontrol.com
1-888-HAY-INDL (1-888-429-4635)
IS3401VSPFC Rev A 12/08/14
Pg. 24 of 36
Reset all parameters
+ for yes; > to skip
Use Timers Menu to
set time clocks.
Are you sure?
+ for yes; - for no
Timer Menu
Press > to enter
Timer 1 1725rpm
Press + to change;
Press > next timer
T1: Timer 1
+/- rename; speed >
Timer 1 1725rpm
Timer 1 1725rpm
Choose Days
7D 7 days a week >