Problem Detected: LED #5,6,7, or 9
LED #5,6,7, or 9
Flashing
(Internal Error)
NO
YES
Did error clear?
YES
NO
Replace Control
Center
p/n
GLXAQR100CTL
Remove power
for 2 mins then
re-apply
Problem solved
Did error clear?
NO
YES
YES
Is salt level
below
4500ppm?
Dilute salt level
to lower than
4500
Is water
temperature
below 104°F?
NO
Did error clear?
NO
Does moving
water fully cover
Cell
Plates?
Clean filter or
clear plumbing
obstruction
NO
Did error clear?
YES
YES
NO
YES
Wait until water
temperature falls
below 104°F
NO
*For verification of diagnosis contact Hayward Technical Support
908-355-7995
Problem Detected with any one of these LED’s illuminated indicates an Internal Error.