32
Problem Detected LED
With LED #8
With “MAX” LED
Reason
Possible Action
No
Current to
Cell
Remove power to the
AquaRite 100
for two
minutes and then re-apply to reset system
Turn on
Super Chlorinate
briefly then go back to
original setting
Inspect
Cell Vessel
and verify
Cell Plates
are fully
covered by moving water
Reason
Possible Action
Cell Error
Remove power to the
AquaRite 100
for two (2)
minutes and then re-apply to reset system
Make sure
Cell Cable
is secure and free of
damage
If error persists, replace the
Cell
(p/n CCELL)
*Make sure cell cable is secure and free of damage. If damage is found or cord does not fit
securely onto cell contact Hayward Technical Support 908-355-7995