18
When these lights illuminate together, the
Cell
reports salt levels below 1500.
Test the salt concentration of the water using an
independent test, with a calibrated salt meter. If the salt
level is
below 1500
, raise the salt level
(
refer to salt
addition table pg. 38)
. If fine, go to 2B.
Test the Salt Level
Step 2A
Desired Salt
Concentration:
1500-4500 PPM
Problem Detected and MIN LED
The
Cell
must be clean in order to report an accurate salt
reading. If the
Cell is dirty,
clean the
Cell
(
steps on
pg.11-12
). If
Cell
is clean, like the image above,
proceed to step 2C.
The cleanliness of the Cell plays a major role in the AquaRite 100’s ability to report salt levels
accurately.
Inspect the Cell
Step 2B
Remove
Calcium and
other debris
from the Cell