26
These lights illuminated together indicate a Temperature Sensor Error.
Cell
should be clean & free of debris. If
Cell
is dirty,
clean the
Cell
.
If
Cell
is clean, replace
Cell (p/n CCELL)
.
Inspect Cell
Problem Detected: LED #4
Remove
Calcium and
other debris
from the Cell
Step 5B
Remove power from the
AQR100
for two minutes.
Re-apply power to reset the system. If error does not
clear continue to step 5B
Turn power off for 2
minutes, then back on
Remove power from AQR100
Step 5A