27
Problem Detected: LED #3 or #4
LED #3 Flashing
(Low input
power)
Did error clear?
YES
NO
Verify input
power is
configured
correctly
Replace Control
Center
p/n
GLXAQR100CTL
Remove power
for 2 mins then
re-apply
Problem solved
Did error clear?
NO
YES
LED #4 Flashing
(Temperature
Sensor error)
Did error clear?
NO
Is
Cell
clean and
free of debris or
calcium?
Remove power
for 2 mins then
re-apply
Problem solved
Clean
Cell
using
procedures on
pg. 11-12
Did error clear?
Replace Cell
p/n CCELL
YES
NO
YES
YES
NO
*For verification of diagnosis contact Hayward Technical Support
908-355-7995