12
The
Cell
draws amperage when power is applied during chlorination. The amperage
draw will be impaired when calcium and other debris exist within the
Cell’s
electrolytic grid; this in turn effects the salt reading and chlorination efficiency.
Using an approved container, mix a solution comprised
of
4 parts water to 1 part Muriatic Acid. Always Add
Acid to Water.
Place
Cell
into plastic bucket, pour solution into bucket.
Solution should
NOT
cover electronic cap. Once clean,
rinse cell, pour solution back into approved container.
Mix: 4 Parts H
2
O / 1 Part Muriatic Acid
Step 3
Step 4
NOTE: ALWAYS ADD ACID TO WATER! NEVER ADD WATER TO ACID.
The cell cleaning solution may be reused a few times.
ALWAYS: STORE MIXED SOLUTIONS IN A SAFE AREA, OUT OF HARMS WAY.
When the solution is depleted, follow the manufacturer’s instructions for proper disposal.
1 Part:
Muriatic Acid
4 Parts:
Water
Carefully Pour Solution into Cell
Cleaning Tip:
The electronic cap
of the Cell should
NOT
be submerged
in water
How To: Clean the Cell (Cont.)