background image

21 

When these lights illuminate together, the 

Cell

 reports salt levels above 4500.  

Test the salt concentration of the water using an 

independent test, with a 

calibrated

 salt meter.  If salt 

level is 

above 4500

, dilute salt level 

(

referring to salt 

dilution calculation on pg. 39)

.  If fine, go to Step 3B. 

If water temperature is 

NOT

 within the proper range, 

wait until the water temperature is between 

65°F  - 

104°F

 .  If the temperature

 IS 

within the proper range 

continue to step 3C. 

Test the Salt Level 

Step 3A 

Step 3B 

Verify water temperature is within range

 

Desired Salt  

Concentration: 

1500-4500 PPM 

Problem Detected: LED #2  

Desired 

Water 

Temperature 

is between 

65°F

 - 

104

°F

 

 

Содержание AquaRite 100

Страница 1: ...AquaRite 100 Troubleshooting Guide TSG AQR100a Copyright 2019 Hayward Industries Inc...

Страница 2: ...Hazardous voltage can shock burn cause serious injury and or death To reduce the risk of electrocution and or electric shock hazards Only qualified technicians should remove the panel Replace damaged...

Страница 3: ...Cell 9 10 11 12 Troubleshooting Pg 13 36 1 Inadequate Water Flow LED 2 Problem Detected with MIN LED or LED 2 3 Problem Detected with LED 3 or LED 4 4 Problem Detected with LED 5 6 7 or 9 5 Problem D...

Страница 4: ...Cell also known as the Cell used throughout this guide Power is sent from the AquaRite 100 Control Center to the Cell when chlorine production is scheduled based on time percentage When power is appli...

Страница 5: ...D C Problem Detected LED D Standing By LED E Generating Chlorine LED F Super Chlorinating LED G Minimum Chlorine Output LED 10 H DAILY CHLORINE OUTPUT LED s I Chlorine Output Adjustment Buttons J Supe...

Страница 6: ...to turn on or is in between generating cycles E Illuminates when unit is actively generating chlorine F Illuminates when unit is SUPER CHLORINATING G The Minimum DAILY CHLORINE OUTPUT amount of chlor...

Страница 7: ...Ideal level 3200 ppm Salt Levels 1 0 3 0 ppm Free Chlorine 7 2 7 8 ppm PH 80 120 ppm Alkalinity 200 400 ppm Calcium Hardness Outdoor Pools 30 50 ppm Indoor Pools 0 ppm Cyanuric Acid Stabilizer 0 ppm...

Страница 8: ...AquaRite 100 How To...

Страница 9: ...ne 1 Black Violet Line 2 N A Neutral Red White Ground Green 240 VAC Wire Colors Line 1 Black Line 2 Red Neutral White Violet Ground Green Power must be turned off at the circuit breaker before perform...

Страница 10: ...put buttons set the level of production during the generating cycle Generating cycles occur in 60 minute increments Each led illuminated from Min to MAX represents 10 or six 6 minutes of chlorine prod...

Страница 11: ...still require cleaning if salt accuracy is off and or chlorine production has diminished Wear Protective Equipment If the Cell requires cleaning always wear all recommended protective equipment such a...

Страница 12: ...ion into bucket Solution should NOT cover electronic cap Once clean rinse cell pour solution back into approved container Mix 4 Parts H2O 1 Part Muriatic Acid Step 3 Step 4 NOTE ALWAYS ADD ACID TO WAT...

Страница 13: ...AquaRite 100 Troubleshooting...

Страница 14: ...power to the pump on AQR 100 is between generating cycles Wait until next generating cycle begins or cycle power to the AquaRite 100 Reason Possible Action No water flow detected Verify pump is on Rem...

Страница 15: ...d on and running Problem Detected Inadequate Flow Step 1A Verify the timer and breaker are in the ON position The cleanliness of the Cell plays a major role in the AquaRite 100 s ability to report sal...

Страница 16: ...Did error clear Replace Cell p n CCELL Problem Detected Inadequate Flow Is pump turned on Did error clear YES NO NO YES Problem solved For verification of diagnosis contact Hayward Technical Support...

Страница 17: ...Inspect Cell Vessell verify Cell Plates are covered by moving water Remove power to the AquaRite 100 for two minutes then re apply to reset system Reason Possible Action High Salt Check the salt leve...

Страница 18: ...ine go to 2B Test the Salt Level Step 2A Desired Salt Concentration 1500 4500 PPM Problem Detected and MIN LED The Cell must be clean in order to report an accurate salt reading If the Cell is dirty c...

Страница 19: ...ed by moving water If NOT fully covered by moving water clear obstructions If error persists go to step 2D Verify moving water fully covers Cell plates Step 2C Remove power to the AQR100 for two minut...

Страница 20: ...Bring salt level within range Did error clear Replace Cell p n CCELL Problem Detected MIN LED Is salt level between 1500 4500ppm Remove power for 2 mins then re apply Did error clear Problem solved D...

Страница 21: ...rring to salt dilution calculation on pg 39 If fine go to Step 3B If water temperature is NOT within the proper range wait until the water temperature is between 65 F 104 F If the temperature IS withi...

Страница 22: ...lt levels above 4500 Problem Detected LED 2 Remove power to the AQR100 for two minutes Re apply power to reset the system If error does not clear replace the Cell p n CCELL Remove power from the AQR10...

Страница 23: ...er for 2 mins then re apply Did error clear Dilute salt level to lower than 4500 Replace Cell p n CCELL Is salt level below 4500ppm Did error clear Problem solved Did error clear NO NO YES YES YES NO...

Страница 24: ...configured for the correct voltage pg of this manual Verify proper voltage to the AquaRite 100 Reason Possible Action Temperature Sensor Error Remove power to AquaRite 100 for two minutes then re appl...

Страница 25: ...ltage Verify proper voltage to AQR100 If error persists replace control p n GLXAQR100CTL Remove power from the AQR100 for two minutes Re apply power to reset the system If error does not clear continu...

Страница 26: ...Cell If Cell is clean replace Cell p n CCELL Inspect Cell Problem Detected LED 4 Remove Calcium and other debris from the Cell Step 5B Remove power from the AQR100 for two minutes Re apply power to r...

Страница 27: ...mins then re apply Problem solved Did error clear NO YES LED 4 Flashing Temperature Sensor error Did error clear NO Is Cell clean and free of debris or calcium Remove power for 2 mins then re apply Pr...

Страница 28: ...two minutes then re apply to reset system Verify salt level is no greater than 4500 ppm Verify water temperature is no greater than 104 F Inspect Cell Vessel and verify Cell Plates are fully covered...

Страница 29: ...ntinue to step 6B Remove power from the AQR100 Problem Detected LED 5 6 7 or 9 Step 6A Test salt level of water using an independent test with a calibrated salt meter If salt level is above 4500 dilut...

Страница 30: ...CTL Verify moving water fully covers cell plates If water temperature is NOT within the proper range wait until it is within range If the temperature IS within range continue to step 6D Step 6C Verify...

Страница 31: ...below 4500ppm Dilute salt level to lower than 4500 Is water temperature below 104 F NO Did error clear NO Does moving water fully cover Cell Plates Clean filter or clear plumbing obstruction NO Did e...

Страница 32: ...ect Cell Vessel and verify Cell Plates are fully covered by moving water Reason Possible Action Cell Error Remove power to the AquaRite 100 for two 2 minutes and then re apply to reset system Make sur...

Страница 33: ...t the system If error does not clear continue to step 7B Remove power from the AQR100 Problem Detected LED 8 Step 7A Press Super Chlorinate button to force generating cycle to begin After a few moment...

Страница 34: ...ed together indicate there is no current to the Cell Cell Cord must be connected securely and be free of damage If error does not clear replace the Control Center p n GLXAQR100CTL Verify Cell Cord is...

Страница 35: ...here is no current to the Cell Verify Cell Cord is securely fastened to Cell Inspect Cell Cord for damage or corrosion Step 8B Turn power off for 2 mins then back on Make sure cell cable is secure and...

Страница 36: ...g water fully cover Cell Plates Clean filter or clear obstruction in plumbing NO Remove power for 2 mins then re apply Is Cell Cable secure and free of damage Is Cell Cable secure and free of damage Y...

Страница 37: ...AquaRite 100 Additional Information...

Страница 38: ...183 200 217 233 250 267 283 300 317 333 2400 53 67 80 93 107 120 133 147 160 173 187 200 213 227 240 253 267 2600 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 2800 27 33 40 47 53 60 6...

Страница 39: ...est Part 2 Subtract the Average Pool Depth by the answer from part 1 This will give you the total number of inches to drain and replenish with fresh water to achieve a salt level of to match desired s...

Страница 40: ...ELL Replacement Cell Only GLXAQR100CCABLE Cell Cable GLXAQR100PCORD Power Cord GLXAQR100CTL AQR 100 Control Center Only GLXAQR100DOOR Door Flap for Display GLXAQR100PCB Main PCB GLXAQR100VESNUT Vessel...

Страница 41: ...0112 Year of Manufacture 3A0112 Month of Manufacture 123456 Manufacturing ID 3A0112 123456 3A11284 123456 Beginning 08 05 2011 Beginning 11 01 2001 3A11284 Standard Warranty Term 3A11284 Product Famil...

Отзывы: