21
When these lights illuminate together, the
Cell
reports salt levels above 4500.
Test the salt concentration of the water using an
independent test, with a
calibrated
salt meter. If salt
level is
above 4500
, dilute salt level
(
referring to salt
dilution calculation on pg. 39)
. If fine, go to Step 3B.
If water temperature is
NOT
within the proper range,
wait until the water temperature is between
65°F -
104°F
. If the temperature
IS
within the proper range
continue to step 3C.
Test the Salt Level
Step 3A
Step 3B
Verify water temperature is within range
Desired Salt
Concentration:
1500-4500 PPM
Problem Detected: LED #2
Desired
Water
Temperature
is between
65°F
-
104
°F