35
Remove power to the
AQR100
for two minutes.
Re-apply power to reset the system. If error does not
clear continue to step 8B.
Remove power from the AQR100
Problem Detected: MAX LED
Step 8A
Inspect Cell cord
These lights illuminated together indicate there is no current to the
Cell
.
Verify
Cell Cord
is securely
fastened to
Cell
Inspect
Cell Cord
for damage or
corrosion
Step 8B
Turn power off for 2
mins, then back on
*Make sure cell cable is secure and free of damage. If damage is found or cord does not fit
securely onto cell contact Hayward Technical Support 908-355-7995
Cell Cord
must be connected securely and be free of
damage. If error does not clear replace the
Control
Center (p/n GLXAQR100CTL)
.