20
MIN LED
Flashing
(Low Salt)
Is
Cell
clean and
free of debris or
calcium?
NO
YES
YES
NO
Clean
Cell
using
procedures on
pg. 11-12
Does moving
water fully cover
Cell Plates
?
NO
Clean filter or
clear plumbing
obstruction
Bring salt level
within range
Did error clear?
Replace Cell
p/n CCELL
Problem Detected: MIN LED
Is salt level
between 1500-
4500ppm?
Remove power
for 2 mins then
re-apply
Did error clear?
Problem solved
Did error clear?
NO
NO
Did error clear?
NO
YES
YES
NO
YES
YES
When these lights illuminate together, the
Cell
reports salt levels below 1500.
*For verification of diagnosis contact Hayward Technical Support
908-355-7995