APEX
™
Exciter Incorporating FLO
™
Technology
RTAC Operating Procedures, Main Screen.
Navigating the LCD Display Screens
26
04s30
0.fm
03/08/07
888-2604-001
Page: 3-57
WARNING: Disconnect primary power prior to servicing.
3.7.5
From RTAC Setup Screen
Up to four Existing RTAC correction setups can be saved. An option to name each saved
filter setup exists. Filter setups can be stored for many reasons, such as when the trans-
mitter was first installed, after transmitter maintenance, and etc. They are good for
comparative testing of the transmitter and RTAC correction.
• Filter Set: (selections include 1 through 4)
• Filter Title: Brings up an alpha/numeric touch keypad to enter the name for the select-
ed filter set.
• Save: Pressing this soft key saves the current RTAC setup to the filter set selected.
The filter set should be given a name (in the filter title selection).
• Restore: Applies the selected, pre-saved filter set to the RTAC correction algorithm.
This causes the Main screen RTAC samples to be set to Default, which applies the
pre-saved filter set to the RTAC correction algorithm.
See Section 3.6.3, RTAC Setup Screen, on page 3-38 for RTAC setup instruction.