19
PC 45 Corn/Pellet Stove
AuTOmATIC IgNITION ESP CONTrOl
Feed adjuster
Sets the maximum
feed rate.
Test
Runs all motors at
full speed for one
m i n u t e t o c h e c k
operation. Afterward
the combustion blower
will go to minimum and
stay there.
Distribution Blower
speed adjustment
range.
L = low
H = high
Variable speed
anywhere between L
and H; although as the
stove temp. goes up,
so does the L and H
scale.
Temp dial
Allows you to adjust the room temperature in Room Temp
Mode using the outer scale marked in degrees Fahrenheit.
It also allows you to adjust the stove temperature while in
Stove Temp Mode using the inner scale marked from 1 to 7.
Mode Selector
Allows you to choose
between Room Temp
Mode, Stove Temp
Mode, or OFF. Also
allows you to vary the
distribution blower
speed by turning the
knob to the high or low
side of each mode.
Power Light
Indicates power to the
control.
Indicates power to the
feed motor.
Indicates igniter is on.
Indicates power to
combustion blower.
Status Light
Will be lit in either stove
or room temp mode
when pointer is not
within off position band
except after normal
shut down. Blinks to
indicate errors listed
below.
Indicates power to
distribution blower.
6 blinks
: Indicates that the control has calculated poor
or incomplete combustion occurring for more than 50
minutes. See Troubleshooting section for more details.
A six blink status may be set if the stove is allowed to
run out of pellets. To reset, turn mode selector to "OFF"
then back on to the desired mode. If the unit was not
out of pellets, see Troubleshooting section, Page 24,
for more details.
* manual reset
- Disconnect the power cord for a few
seconds and reconnect. If error still occurs call your
Harman Dealer.
3 blinks:
Indicates that the ESP (Exhaust Sensing
Probe) has gone out of range too many times in a
specified time. Perform a manual reset*, If the code
returns immediately, the ESP may be damaged or
disconnected. Otherwise, the exhaust system may
need cleaned..
4 blinks:
Can occur only in Room Temp Mode and
indicates Room Sensing Probe failed or not installed.
If a Room Sensing Probe is then installed, the status
light will automatically reset.
NOTE: Unit will not start in "AUTO" with this status error.
5 blinks (In Igniter Auto. mode Only):
Indicates that
the unit has failed to light within the 45 minute start
cycle. To reset - Turn Mode Selector to "OFF", then turn
to either mode again.
Dealer Diagnostic Port
For dealer maintenance use only.
Requires special DDM monitor
supplied to Harman Dealers
exclusively.
Status light error message
Igniter switch
Set to appropriate
Start-Up mode.