PC 45 Corn/Pellet Stove
Installation
When installing this unit in a mobile home several requirements must
be followed:
1. The unit must be bolted to the floor. This can be done with
1/4" lag screws through the 2 holes in the base plate.
2. The unit must also be connected to outside air. See page 7.
3. Floor protection and clearances must be followed as shown.
4. Unit must be grounded to the metal frame of the mobile home.
CAuTION: This appliance must be vented to the outside.
Due to high temperatures, the stove should be placed out of traffic and away from
furniture and draperies.
Children and adults should be alerted to the hazards of high surface
temperatures and should stay away to avoid burn to skin and/or clothing.
Young children should be carefully supervised when they are in the same
room as the stove.
Clothing and other flammable materials should not be placed on or near
this unit.
Installation and repair of this Harman Stove should be done by a qualified
service person. The appliance should be inspected before use and at least
annually by a qualified service person. More frequent cleaning will be
required. It is imperative that control compartments, burners, and circulating
air passageways of the stove be kept clean.
Fig. 3
9"-13"
9"-13"
9" With Side Shields
13" Without Side Shields
Fig. 4
Fig. 6: Refer to page
20 for detailed draft
settings and adjustment
procedures.
mobile home installation should be done in accordance with the
manufactured home and Safety Standard (hud), CFr 3280, Part 24.
Place the stove on a noncombustible floor or a floor protector; a
minimum of 3/8" material with .84 k value per inch. Floor protection
must extend 6 inches to the front, 6 inches to the sides and 1 inch
to the rear of the stove. Place the stove away from combustible
walls at least as far as shown in figures 3,4 & 5. Please note the
difference in side wall clearance with and without side shields.
Note that the clearances shown are minimum for safety but do
not leave much room for access when cleaning or servicing. Please
take this into account when placing the stove. INSTALL VENT AT
CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
Connect the power cord to a 120 V.A.C. 60Hz grounded
receptacle. (A surge protector is recommened to protect the
circuit board).
Prior to installing the flue pipe, connect a draft meter to the
stove as shown in fig. 6. (The draft meter must have a minimum
range of 0"- 0.5"). Turn stove to "TEST" Mode and record the
draft reading ______. After the flue pipe is connected, check the
draft reading again making sure all doors and windows in the
home are closed. If this reading is more than.05" higher than the
unconnected reading, check for possible restrictions or the need
for outside air. (See page 7). Clearances may only be reduced
using methods approved by the regulating authority or NFPA-211.
wArNINg!- dO NOT INSTAll IN A rOOm dESIgNATEd FOr SlEEPINg.
CAuTION: ThE STruCTurAl INTEgrITY OF ThE mANuFACTurEd hOmE
FlOOr, wAll, ANd CEIlINg/rOOF muST bE mAINTAINEd.
location
mobile home Installation
Fig. 5
18"
Содержание PC45
Страница 2: ......
Страница 39: ...39 PC 45 Corn Pellet Stove Service Maintenance Log Date Of Service Performed By Description Of Service ...
Страница 40: ...40 pC 45 Corn pellet Stove Service Maintenance Log Date Of Service Performed By Description Of Service ...
Страница 41: ......
Страница 42: ...Proudly Printed On 100 Recycled Paper ...