PC 45 Corn/Pellet Stove
The PC45 corn/pellet stove is more than just automatic ignition, it is also automatic temperature
control. The automatic system will allow the fire size to be adjusted to match the heating needs and
even put the fire out if necessary. If heat is needed after the fire is out, the PC 45 will automatically
re-ignite and adjust the fire size to match the heating need. The totally automatic room sensor mode
is recommended because of its efficiency. The unit can be switched between "AUTO" and "MANUAL"
at any time during operation.
AuTOmATIC IgNITION/OPErATION
Fig. 19:
Room Temperature Mode:
This setting will produce
a room temperature of 70 degrees with the distribution blower
at medium speed.
This setting will produce medium heat with the distribution
blower on "low".
Fig. 20:
This setting will produce continuous maximum heat
output with the distribution blower at full speed.
Stove Temperature mode
To kill the fire or stop burning the stove, turn the Mode Selector
to "OFF". This will cause the fire to diminish and burn out. When
the fire burns out and the stove cools down everything will stop.
NOTE: The combustion blower motor will be the last
component to stop.
This insures that all fuel in the burnpot
and ashes located in the ash pan are completely cold before
shut down of the combustion motor.
If you pull the plug to shut down the stove, all motors will stop.
This may cause incomplete combustion and smoke in the firebox.
If the load door is opened the smoke may escape.
The best way to shut down the stove is to simply let it run out
of fuel, then the stove will shut down automatically.
In "Room Temp Mode" heat output is controlled automatically
by the Room Sensing Probe. When the Room Sensing Probe
calls for heat, the stove will increase output. When the Room
Sensing Probe is getting close to the set temperature, the stove
will begin to level off output and keep the fire burning at just the
right temperature to maintain that setting.
High output is determined by the feed rate setting. This setting,
generally on #2 (corn) or #4 (pellet), can be increased if higher
burn rates are necessary.
When burning corn the feed rate setting can be adjusted
anywhere within the yellow range with a #3 setting being the
maximum setting, #1 the lowest setting. This setting will vary
depending on the quality of corn used.
When burning pellets the feed rate setting can be adjusted
within the full range between #1 on the low side to #6 on the
high side.
Overfeeding is not a safety concern, but the fire may be pushed
off the burnpot and extinguish in the ash pan.
In "Room Temp Mode" a constant fuel consumption rate is
sacrificed for exact room temperature. Therefore, as it gets colder
more fuel will be burned automatically.
The distribution blower speed will vary according to the position
of the mode selector pointer, and fire size.
This allows for automatic ignition upon start-up only. The unit
can then be set at any desired setting. The heat output and fuel
consumption will remain constant regardless of room temperature.
The unit's low burn or maintenance setting is as low as it will
go. It will not go out unless it runs out of fuel or is turned off.
Shut-down Procedure
Stove Temperature mode
Igniter Switch to "AuTO"
room Temperature mode
Igniter Switch to "AuTO"
Содержание PC45
Страница 2: ......
Страница 39: ...39 PC 45 Corn Pellet Stove Service Maintenance Log Date Of Service Performed By Description Of Service ...
Страница 40: ...40 pC 45 Corn pellet Stove Service Maintenance Log Date Of Service Performed By Description Of Service ...
Страница 41: ......
Страница 42: ...Proudly Printed On 100 Recycled Paper ...