![Harman PC45 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/harman/pc45/pc45_installation-and-operating-manual_598401022.webp)
22 PC 45 Corn/Pellet Stove
ESP Probe
Fig. 37
Be careful not to
damage ESP probe
when cleaning with
brush.
maintenance
Fig. 31:
Latch "closed "with
blower cover in place.
Fig. 32
ESP probe
Fig. 33:
Exposed blower
wheel and flue opening,
NOTE: ESP probe is visible.
Fig. 34: Blower cover
removed.
8. Use a brush to clean the flue, being careful not to
damage the ESP probe. The flue goes straight through
into the vent pipe therefore, the vent pipe can also be
cleaned to some extent through the flue outlet.
9. Reinstall the blower cover and relatch.
10. Slide the ash pan into the stove and close and latch
the door.
NOTE: ASHES MAY BE FINER THAN YOUR VACUUM
FILTER. USE CAUTION WHEN VACUUMING AND
KEEP FILTER CLEAN.
Fig. 36: For further details see exploded view on page 22.
Fuel Fines may
build up in this
area
(Cleaning continued)
5. Remove the ash pan.
6. Remove the combustion blower cover by turning the
blower cover latch vertical as shown in fig. 32. Slide
the cover out of the slot on the left. This will expose
the combustion blower wheel and flue outlet, fig. 33.
7. Clean the blower wheel with a brush and a vacuum
cleaner.
Formation and Need For Removal- The products
of combustion will contain small particles of fly ash.
The fly ash will collect in the exhaust venting system
and restrict the flow of the flue gases. Incomplete
combustion, such as occurs during startup, shutdown,
or incorrect operation of the room heater, will lead to
some soot formation which will collect in the exhaust
venting system. The exhaust venting system should be
inspected after the first month of burning to determine
the frequency of cleaning that will be required, and at
least yearly thereafter. NOTE: The frequency could vary
from once a month to once a season depending on the
quality of the fuel being used.
If You Experience A Chimney Fire; Do NOT disconnect
power to the appliance. Do NOT put water on the fire.
Turn the selector dial to the OFF position and allow the
unit to shut down on its' own. Have the applaince and
venting system professionally inspected and cleaned
prior to using.
Soot and Fly Ash
1. Remove the rear shields to access the feeder cover.
2. Remove the wing nut on the feeder cover and slide
the cover off the threaded rod.
3. Remove all fines with a vacuum.
4. Replace the feeder cover and rear shields.
Cleaning of Feeder Fines Area