10 PC 45 Corn/Pellet Stove
Fig. 11
Fig. 12
venting
This method provides excellent venting for normal
operation. This method also provides natural draft in
the event of a power failure. If the chimney condition
is questionable you may want to install a liner as in
method #6. Check with your local regulations, some
municipalities require a complete liner.
This method provides excellent venting for normal
operation. This method also provides natural draft in
the event of a power failure.
The damper area must be sealed with a steel plate.
Kaowool, mineral wool or an equivalent non-combustible
insulation is recommended to be installed on top of the
sealing plate to reduce the possibility of condensation.
The connector pipe should extend through the smoke
chamber to the base or into the first flue tile. A cap
should be installed on the chimney to keep out rain. If
the chimney condition is questionable you may want
to install a liner all the way to the top as in method #5.
Check with your local regulations, some municipalities
require a complete liner.
Chimney must be of a type suitable for solid fuel
burning.
Chimney and connector must be maintained in
good condition and kept clean.
Chimney must be of a type suitable for solid fuel
burning.
Chimney and connector must be maintained in
good condition and kept clean.
#3 Installing into an existing chimney
#4 Installing into an existing fireplace