54
T e c h n i c a l D a t a /
t r o u b l e s h o o t i n g E L 4 0
(EL = electronic version)
Halogen G4
12 V/10W
Removing halogen spotlight
Turn cover counter clockwise and remove it.
The halogen bulbs (
12 Volt/10 Watt
) are available from an
electrician. Do not touch the halogen bulbs with your hand.
Steam bath
Shower Temple 100 EL 40 cannot used in connection with a
steam bath! No humidity on the electronic components is
allowed.
Combination boiler
The Shower Temple 100 EL 40 with 1/2” thermostat cannot
be used with a combination boiler.
Hot water supply
The hot water supply must be at least 2° C higher than the
desired mixed water temperature. The temperature difference
on the supply connection should be 50° C.
Pressure fluctuations
Any fluctuations between the cold and hot water supply must
be balanced.
Technical Data
Power supply:
230V~ 50/60Hz
Rated output:
35 VA
Transformer:
Protection Class II
Protection type:
IP 65
Minimum water pressure:
1.5 bar
Recommended pressure:
2 - 5 bar
Test pressure:
10 bar
Hot water temperature:
max. 70° C
Recommended hot water
temperature:
60° C
Safety stop:
42°C
Flow rate at 3 bar pressure
Over head shower:
22 l/min
Hand shower:
13 l/min
Body showers:
18 l/min
Hand s body showers:
26 l/min
Over head body showers
28.5 l/min
Over head s hand showers
31.5 l/min