55
English
T e c h n i c a l D a t a /
t r o u b l e s h o o t i n g E L 4 0
(EL = electronic version)
Failure
Possible cause
Remedy
No function
No current available
Check current conductor
Transformer defect
Replace transformer
Contact manufacturer service
Light fails
Connection to the lighting
Plug in the connector of the lights
is interupted
One halogen
Halogen spotlight defect
Replace halogen bulb (12 V/10 Watt)
spotlight fails
No water flow
Floor shut-off device is closed
Open floor shut-off device
when using
Shut-off valve (Thermostat)
the shower
is closed
Open shut-off valve
Filters are polluted
Clean filter
(Servicing thermostat)
After a certain time
Not enough stored
Increase hot water storage or
of showering the
hot water
temperature of the water stored
temperature changes
Outlet temperature does
Temperature of the feed
Increase the temperature of the
not correspond with the
hot water is too low
hot water cylinder
adjusted temperature
No motor alignment was
Perform motor alignment
performed