47
English
O p e r a t i n g / s e r v i c i n g E L 4 0
(EL = electronic version)
Motor adjustment
The motor should be adjusted
after the Shower Temple has
been put into operation to
adapt it to local home
conditions. These depend on
the type of heating used and
the available warm water
temperature.
Attention:
These specifica-
tions can change later when
a heating system is installed
or modified, or the water
temperature is changed.
Attention:
Water emerges: Therefore
check the position of the
hand shower!
The lighting switches off
automatically after the shower.
Factory setting: 2 minutes;
individually adjustable
1 – 50 min (refer to Page 50)
Pressing the
>42° (
)
button stops motor adjustment
prematurely (the last valid
factory setting curve is then
applicable).
…and it is as simple
as this:
The Shower Temple must be in
"stand-by" mode (display has
background lighting, no func-
tions are active). The hand
shower is activated automati-
cally during motor adjustment.
First press the
>42° (
)
button
as well as
the
Body
shower (
)
button until
tCH
is displayed.
Now press the
Mode
-button
(
)
: Motor adjustment now
runs automatically. It takes ab-
out 7 minutes.
Pressing the
Mode (
)
button saves the motor
adjustment.
The letter
C
is displayed when
motor adjustment has finished.
Light on/off
The shower lighting can be
switched on and off with the
Light (
)
button.